Објављен
ISO 16773-2:2016 gives guidelines for optimizing the collection of EIS data with focus on high-impedance systems. High impedance in the context of intact coatings refers to systems with an impedance greater than 109 Ω⋅cm2. This does not preclude measurements on systems with lower impedance. For uncoated samples extra information can be found in ISO/TR 16208.
ISO 16773-2:2016 deals with the following:
- instrumental set-up: requirements and pit-falls;
- data validation: checking the measurement range and the accuracy of the data;
- performing an EIS measurement: specimen considerations and instrumental parameters;
- the experimental results: different methods of presenting EIS data.
These guidelines are intended to ensure the acquisition of EIS data that can be used to study the performance of the specimen. This part of ISO 16773 does not give guidelines for the interpretation of the data.
ПОВУЧЕН
ISO 16773-2:2007
ОБЈАВЉЕН
ISO 16773-2:2016
90.20
Почетак поступка преиспитивања стандарда
15. 4. 2026.
Spektroskopija elektrohemijske impedancije (EIS) na metalnim uzorcima sa prevlakom i bez nje — Deo 2: Prikupljanje podataka
60.60 Стандард објављен