Phone: (011) 7541-421, 3409-301, 3409-335, 6547-293, 3409-310
E-mail: Standards sales: prodaja@iss.rs Education: iss-edukacija@iss.rs Information about standards: infocentar@iss.rs
Stevana Brakusa 2, 11030 Beograd
Main menu

IEC 62828-2 ED2

Reference conditions and procedures for testing industrial and process measurement transmitters - Part 2: Specific procedures for pressure transmitters

General information

50.20     Mar 6, 2026

PRVD    Apr 17, 2026

IEC

TC 65/SC 65B

International Standard

17.100     25.040.40  

Scope

IEC 62828-2:2026 establishes specific procedures for testing pressure process measurement transmitters (PMT) used in measuring and control systems for industrial processes and for machinery.
A pressure PMT can feature a remote seal to bring the process variable to the sensing element in the PMT. When the remote seal cannot be separated from the PMT, the complete device is tested.
For general test procedures, reference is made to IEC 62828-1, which is applicable to all types of process measurement transmitters.
NOTE In industrial and process applications, to indicate the process measurement transmitters, it is common also to use the terms "industrial transmitters", or "process transmitters".
This second edition cancels and replaces the first edition published in 2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) revision according to the latest IEC rules;
b) comparison with the general part of IEC 62828-1;
c) additions and more precise definitions in the “Terms and definitions” clause;
d) correction of the calculation formulas for the measurement error;
e) more precise formulation of long-term drift;
f) extension of additional tests;
g) transfer of the annex “Example of signal current range for a 4 to 20 mA PMT” in IEC 62828-1;
h) new Annex C “Main characteristics for pressure transmitters”.

Life cycle

PREVIOUSLY

PUBLISHED
IEC 62828-2:2017 ED1

NOW

PROJECT
IEC 62828-2 ED2
50.20 Proof sent to secretariat or FDIS ballot initiated: 8 weeks
Mar 6, 2026

National adoptions

Reference conditions and procedures for testing industrial and process measurement transmitters - Part 2: Specific procedures for pressure transmitters

50.20   Proof sent to secretariat or FDIS ballot initiated: 8 weeks

N065 more

Preview

To view the full content, you need to register or to log in to your account by clicking on the "Log in" button

Login