Phone: (011) 7541-421, 3409-301, 3409-335, 6547-293, 3409-310
E-mail: Standards sales: prodaja@iss.rs Education: iss-edukacija@iss.rs Information about standards: infocentar@iss.rs
Stevana Brakusa 2, 11030 Beograd
Main menu

ISO 80601-2-69:2026

Medical electrical equipment — Part 2-69: Particular requirements for the basic safety and essential performance of oxygen concentrator equipment

Apr 10, 2026

General information

60.60     Apr 10, 2026

ISO

ISO/TC 121/SC 3

International Standard

11.040.10  

English   French  

Buying

Published

Language in which you want to receive the document.

Scope

This document is applicable to a transit-operable and non-transit-operable oxygen concentrator. This document is applicable to an oxygen concentrator integrated into or used with other medical devices, ME equipment or ME systems.
EXAMPLE 1           An oxygen concentrator with integrated oxygen conserving equipment  function or humidifier function.
EXAMPLE 2           An oxygen concentrator used with a flowmeter stand.
EXAMPLE 3           An oxygen concentrator as part of an anaesthetic system for use in areas with limited logistical supplies of electricity and anaesthetic gases[2].
EXAMPLE 4           An oxygen concentrator with an integrated liquid reservoir function or gas cylinder filling system function.
This document is also applicable to those accessories intended by their manufacturer to be connected to an oxygen concentrator, where the characteristics of those accessories can affect the basic safety or essential performance of the oxygen concentrator.
NOTE 2     Such accessories can include, but are not limited to, masks, cannulae, extension tubing, humidifiers, carts, carrying cases, external power sources and oxygen conserving equipment.
This document does not specify requirements for oxygen concentrators for use with a medical gas pipeline system.
If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.
Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of the general standard.
NOTE 3     See also 4.2 of the general standard.

Life cycle

PREVIOUSLY

WITHDRAWN
ISO 80601-2-69:2020

NOW

PUBLISHED
ISO 80601-2-69:2026
60.60 Standard published
Apr 10, 2026

National adoptions

Medical electrical equipment - Part 2-69: Particular requirements for the basic safety and essential performance of oxygen concentrator equipment (ISO/FDIS 80601-2-69:2025)

50.60   Close of voting. Proof returned by secretariat

Z076 more