This document gives requirements for the design, fabrication, inspection, testing and verification of GRP tanks and vessels with or without thermoplastics lining for storage or processing of fluids, factory made or site built, non-pressurized or pressurized up to 10 bar, for use above ground. Further requirements are presented in normative Annex G.
The terms vessels and tanks as used in this document include branches up to the point of connection to pipe work or other equipment by bolting and supports, brackets or other attachments bonded directly to the shell.
Fatigue is not considered a design criterion, as keeping strains below the limit strain inherently prevents fatigue failure. This document is applicable to vessels and tanks exposed to temperatures between -40 °C and 120 °C.
This document does not apply to:
- tanks and vessels for the transport of fluids;
- underground storage tanks;
- spherical vessels;
- vessels and tanks of irregular shape;
- tanks and vessels with double containment where the double wall is considered structural;
- tanks and vessels which are subject to the risk of explosion, or failure of which can cause an emission of radioactivity;
- specification for fibre reinforced cisterns of one piece and sectional construction for the storage, above ground, of cold water (see EN 13280).
NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.
Directive 2014/68/EU of the European Parliament and of the Council of 15 May 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of pressure equipment
PUBLISHED
SRPS EN 13121-3:2017
PROJECT
dnaSRPS EN 13121-3:2021
50.20
Proof sent to secretariat or FDIS ballot initiated: 8 weeks
Apr 23, 2026
To view the full content, you need to register or to log in to your account by clicking on the "Log in" button