Phone: (011) 7541-421, 3409-301, 3409-335, 6547-293, 3409-310
E-mail: Standards sales: prodaja@iss.rs Education: iss-edukacija@iss.rs Information about standards: infocentar@iss.rs
Stevana Brakusa 2, 11030 Beograd
Main menu

delSRPS EN 12504-5:2023

Testing concrete in structures — Part 5: Determination of concrete cover using electromagnetic covermeters

General information

40.98     Sep 19, 2025

90.00    Oct 30, 2029

ISS

U071

European Norm

91.100.30  

English  

Scope

This document gives recommendations on and describes the principles of operation of electromagnetic devices that may be used for estimating the position, depth and size of reinforcement buried in concrete. It also describes their methods of use and applications, the accuracy to be expected and the factors which may influence the results.

Electromagnetic covermeters can be used for:
a) quality control, to ensure correct location and cover to reinforcing bars after concrete placement;
b) investigation of concrete members for which records are not available or need to be checked;
c) location of reinforcement as a preliminary to some other form of testing in which reinforcement should be avoided or its nature considered, e.g. extraction of cores, ultrasonic pulse velocity measurement or “near-to-surface” methods;
d) location of buried ferromagnetic objects other than reinforcement, e.g. water pipes, steel joists, lighting conduits.

Life cycle

NOW

ABANDON
delSRPS EN 12504-5:2023
40.98 Project deleted
Sep 19, 2025

Related project

Adopted from prEN 12504-5 IDENTICAL