Phone: (011) 7541-421, 3409-301, 3409-335, 6547-293, 3409-310
E-mail: Standards sales: prodaja@iss.rs Education: iss-edukacija@iss.rs Information about standards: infocentar@iss.rs
Stevana Brakusa 2, 11030 Beograd
Main menu

naSRPS EN 12390-11:2024

Testing hardened concrete - Part 11: Determination of the chloride resistance of concrete, unidirectional diffusion

General information

40.10     Aug 18, 2025

40.20    Oct 16, 2025

ISS

U071

European Norm

91.100.30  

English  

Scope

This document describes a method for determining the unidirectional apparent chloride diffusion coefficient and surface concentration of conditioned specimens of hardened concrete. The test method enables the determination of the chloride penetration after a specified length of curing and length of exposure to NaCl solution.
Since resistance to chloride penetration depends on ageing which includes the effects of continual hydration and interactions with the chloride solution, then the apparent diffusion coefficient also changes with age. A procedure to determine this ageing, expressed here by an ageing exponent, is included in this document and described in Annex A.
The test procedure does not apply to concrete with surface treatments such as silanes and it does not apply to concrete containing fibres (see E.1).

Life cycle

PREVIOUSLY

PUBLISHED
SRPS EN 12390-11:2017

NOW

PROJECT
naSRPS EN 12390-11:2024
40.10 harmonizedStageCodeLabel.40.10
Aug 18, 2025

Related project

Adopted from prEN 12390-11 IDENTICAL