naSRPS EN 12390-12:2024

Testing of hardened concrete - Part 12: Determination of the carbonation resistance of concrete - Accelerated carbonation method

General information

45.99     Jul 2, 2026

50.20    Aug 27, 2026

ISS

U071

European Norm

91.100.30  

English  

Scope

This document describes a method for evaluating the carbonation resistance of concrete using test conditions that accelerate carbonation. After a defined period of curing and a period of preconditioning, the test is carried out under controlled exposure conditions using an increased level of carbon dioxide.
NOTE The test performed under reference conditions takes a minimum of 112 days comprising a minimum age of the specimen prior to curing under water of 28 days, a minimum preconditioning period of 14 days and an exposure period to increased carbon dioxide level of 70 days.
This procedure is not a method for the determination of carbonation depths in existing concrete structures.

Life cycle

PREVIOUSLY

PUBLISHED
SRPS EN 12390-12:2020

NOW

PROJECT
naSRPS EN 12390-12:2024
45.99 Dispatch of FV draft to CCMC
Jul 2, 2026

Related project

Adopted from FprEN 12390-12 IDENTICAL