prSRPS EN 1491:2025

Building valves - Expansion valves - Tests and requirements

General information

10.99     May 13, 2025

ISS

U165

European Norm

English  

Scope

This document specifies dimensions, materials and performance requirements (including methods of
test) for expansion valves, of nominal sizes from DN 15 to DN 32, having working pressures1) from
0,1 MPa (l bar) to 1,0 MPa (10 bar).
Expansion valves are intended for fitting to the cold potable water supply of storage water heaters, having
a maximum distribution temperature of 95 °C, for all energy sources.
Expansion valves do not control the temperature and alone do not constitute the protection required for
storage water heaters. Expansion valves limit pressure, in the water heaters to what they are fitted, that
is produced by thermal expansion of the water.
NOTE The use of the device specified in this document does not override the need to use controls (e.g.
thermostats and cut-outs) which act directly on the power sources of water heaters (for more information see
Annex A).

Related directives

NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.

98/83/EC

Quality of water intended for human consumption

Life cycle

PREVIOUSLY

PUBLISHED
SRPS EN 1491:2023

NOW

PROJECT
prSRPS EN 1491:2025
10.99 New project approved
May 13, 2025

Related project

Adopted from prEN 1491 rev IDENTICAL