This part of EN 50561 applies to equipment using powerline communication technology and intended to be installed in industrial PV sites.
The document specifies limits and methods of measurement of radio disturbance characteristics for equipment that communicates over the AC low voltage power lines in the frequency range 0,5 MHz to 12 MHz, and that utilises a signal path between phase to phase or phase to neutral.
Procedures are given for the measurement of signals generated by the equipment and limits are specified within the frequency range 9 kHz to 400 GHz. No measurement is required at frequencies where no limit is specified.
NOTE The requirements defined in this standard effectively restrict the intended power line transmission frequencies to below 12 MHz
The requirements defined in this standard are for PLC functions of the equipment. For functions other than PLC, the requirements given in other applicable product standards shall be applied.
The radiated emission requirements in this standard are not intended to be applicable to the intentional transmissions from a radio-transmitter as defined by the ITU, nor to any spurious emissions emitted by the radio-transmitter. Specific requirements for the radio function, if any, can be found in the ETSI 301489 series of standards.
NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.
Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)
Directive 2014/53/EU of The European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999/5/EC
PROJECT
prSRPS EN 50561-5:2025
10.99
New project approved
Jul 30, 2025