SRPS ISO 5167-2:2007

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 2: Orifice plates

Jul 25, 2007
95.99   Withdrawal of Standard   Apr 27, 2012

General information

95.99     Apr 27, 2012

ISS

M115

International Standard

17.120.10  

English  

Buying

Withdrawn

Language in which you want to receive the document.

Scope

ISO 5167-2:2003 specifies the geometry and method of use (installation and operating conditions) of orifice plates when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit.
It also provides background information for calculating the flow-rate and is applicable in conjunction with the requirements given in ISO 5167-1.
ISO 5167-2:2003 is applicable to primary devices having an orifice plate used with flange pressure tappings, or with corner pressure tappings, or with D and D/2 pressure tappings. Other pressure tappings such as vena contracta and pipe tappings have been used with orifice plates but are not covered by ISO 5167-2:2003.
ISO 5167-2:2003 is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase. It is not applicable to the measurement of pulsating flow. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or for pipe Reynolds numbers below 5 000.

Life cycle

PREVIOUSLY

WITHDRAWN
SRPS L.H2.015:1989

NOW

WITHDRAWN
SRPS ISO 5167-2:2007
95.99 Withdrawal of Standard
Apr 27, 2012

REVISED BY

WITHDRAWN
SRPS EN ISO 5167-2:2012

PUBLISHED
SRPS EN ISO 5167-2:2022

Related project

Adopted from ISO 5167-2:2003