SRPS CEN/TS 13381-1:2008

Test methods for determining the contribution to the fire resistance of structural members - Part 1: Horizontal protective membranes

Oct 9, 2008
95.99   Withdrawal of Standard   Jul 28, 2015

General information

95.99     Jul 28, 2015

ISS

Z021/PKS U092

Technical Specification

13.220.50     13.220.99     91.080.01     91.220  

English  

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This Part of this European Prestandard specifies a test method for determining the ability of a horizontal protective membrane, when used as a fire resistant barrier, to contribute to the fire resistance of horizontal structural building members.
This European Technical Specification contains the fire test which specifies the tests which are carried out whereby the horizontal protective membrane, together with the structural member to be protected, is exposed to a fire test according to the procedures defined herein. The fire exposure, to the temperature/time curve given in EN 1363-1, is applied to the side which would be exposed in practice and from below the membrane itself.
The test method makes provision, through specified optional additional procedures, for the collection of data which can be used as direct input to the calculation of fire resistance according to the processes given within EN 1992-1-2, EN 1993-1-2, EN 1994-1-2 and EN 1995-1-2.
A related test method for determining the contribution to the fire protection of vertical structural members by vertical protective membranes is given in Part 2 of this ENV.
This European Technical Specification also contains the assessment which provides information relative to the analysis of the test data and gives guidance for the interpretation of the results of the fire test, in terms of loadbearing capacity criteria of the protected horizontal structural member.
The limits of applicability of the results of the assessment arising from the fire test are defined, together with permitted direct application of the results to different structures, membranes and fittings.
This European Technical Specification applies only where there is a gap and a cavity between the horizontal protective membrane and the structural building member. Otherwise the test methods in ENV 13381-3, ENV 13381-4 or ENV 13381-5, as appropriate, apply.
Tests shall be carried out without additional combustible materials in the cavity.

Related directives

NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.

89/106/EEC

Construction products

305/2011

Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec

Life cycle

NOW

WITHDRAWN
SRPS CEN/TS 13381-1:2008
95.99 Withdrawal of Standard
Jul 28, 2015

REVISED BY

WITHDRAWN
SRPS EN 13381-1:2015

Related project

Adopted from CEN/TS 13381-1:2005