This document specifies requirements for above ground single static thermoplastic tanks of volume 450 l to 10 000 l, which can be used for the storage of liquids other than water including chemicals classified as dangerous goods.
This document only applies to tanks manufactured by blow moulding or rotational moulding of polyethylene, with or without reinforcements, which are not subjected to pressures exceeding ± 5 kPa (± 0,05 bar). Except for periodic temperature fluctuation their normal operating temperature does not exceed 25 °C.
This document only applies to tanks with a maximum lifetime of 10 years.
This document specifies permitted materials, performance requirements and test methods and factory production control tests.
This document does not consider wind and snow loads.
NOTE National and/or International regulations above and beyond the requirements of this standard may apply to the storage of liquids and the installation of tanks.
NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.
Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec
WITHDRAWN
SRPS EN 13575:2008
95.99
Withdrawal of Standard
Sep 23, 2013
PUBLISHED
SRPS EN 13575:2013