SRPS EN 12350-4:2008

Testing fresh concrete - Part 4: Degree of compactability

Dec 29, 2008
95.99   Withdrawal of Standard  

General information

95.99    

ISS

U071

European Norm

91.100.30  

English  

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This standard specifies a method for determining the consistency of fresh concrete by determining the degree of compactability. It is not applicable to concrete of which the maximum size of aggregate exceeds 63 mm. If the degree of compactability is less than 1,04 or more than 1,46, the concrete has a consistency for which the degree of compactability test is insensitive.

Related directives

NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.

89/106/EEC

Construction products

305/2011

Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec

Life cycle

NOW

WITHDRAWN
SRPS EN 12350-4:2008
95.99 Withdrawal of Standard

REVISED BY

WITHDRAWN
SRPS EN 12350-4:2010

Related project

Adopted from EN 12350-4:1999