SRPS EN 61300-3-2:2009

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examinations and measurements - Polarization dependent loss in a single-mode fibre optic device

Sep 30, 2009

General information

60.60    

ISS

N086

European Norm

33.180.20  

English  

Buying

Published

Language in which you want to receive the document.

Scope

IEC 61300-3-2:2009(E) specifies measurement methods to determine the dependence of loss in a single-mode fibre optic device to changes in polarization. This procedure focuses on measurements with a fixed wavelength source; therefore, this procedure is applicable to devices whose properties at a single wavelength can represent those over the broader wavelength band. Typical examples of such devices are single-mode interconnecting devices and passive components, including connectors, splices, branching devices, attenuators, isolators, and switches. The maximum observed variation in transmission loss is referred to as polarization-dependent-loss (PDL). This edition includes both the all-states method of the previous edition as well as the Mueller matrix method from IEC 61300-3-12.

Life cycle

NOW

PUBLISHED
SRPS EN 61300-3-2:2009
60.60 Standard published

Related project

Adopted from EN 61300-3-2:2009