SRPS EN 15741:2010

Animal feeding stuffs - Determination of OC-pesticides and PCB’s by GC/MS

Apr 26, 2010
95.99   Withdrawal of Standard   May 29, 2020

General information

95.99     May 29, 2020

ISS

E034-4/PKS E034-10

European Norm

65.120  

English  

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This European Standard specifies a gas chromatographic/mass spectrometric method for the determination of organochlorine pesticides (OC’s) and polychlorinated biphenyls (PCBs) in animal feeding stuffs and oil.
The method is applicable to animal feeding stuffs with a water content up to about 20 wt% and oil/fatty samples containing residues of one or more of the following OC’s and PCBs and some of their isomers and degradation products:
 Aldrin;
 Dieldrin;
 Chlordane (= sum of Chlordane isomers and Oxychlordane);
 DDT (= sum of isomers op'-DDT, pp'-DDT, pp'-TDE (pp'-DDD), and pp'-DDE);
 Endosulfan (sum of -/-isomers and Endosulphanesulphate);
 Endrin;
 Heptachlor (= sum of Heptachlor and -Heptachlorepoxide);
 Hexachlorobenzene (HCB);
 Hexachlorocyclohexane isomers -HCH (-BHC), -HCH (-BHC), -HCH (-BHC or lindane);
 PCB 28, 52, 101, 138, 153 and 180 (“Indicator PCBs”) and PCB-198, 209.
The method is not yet applicable to Chlorocamphene (Toxaphene), a complex mixture of polychlorinated camphenes. Chlorocamphene has a very distinctive chromatographic profile and is easily recognisable by GC/ECD. Positive identification of the toxaphene isomers can be performed by negative chemical ionisation mass spectrometry (NCI-MS), electron impact tandem mass spectrometry (EI-MSxMS) or electron impact high resolution mass spectrometry (EI-HRMS) [1], which is not within the scope of this method.
The limit of quantification for the mentioned organochlorine pesticides and PCBs is 5 ng/g in general. However, 10 ng/g applies for Heptachlor Aldrin, Endrin, Dieldrin, and Endosulfan (-, - and sulphate). Individual laboratories are responsible to ensure that the equipment they used will achieve these limits of quantifications.

Related directives

NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.

70/373/EC

Council Directive 70/373/EEC of 20 July 1970 on the introduction of Community methods of sampling and analysis for the official control of feeding-stuffs

Life cycle

NOW

WITHDRAWN
SRPS EN 15741:2010
95.99 Withdrawal of Standard
May 29, 2020

REVISED BY

PUBLISHED
SRPS EN 15741:2020

Related project

Adopted from EN 15741:2009