Published
(1)P This Part 1-2 of EN 1996 deals with the design of masonry structures for the accidental situation of fire exposure, and is intended to be used in conjunction with EN 1996-1-1, EN 1996-2, 1996-3 and EN 1991-1-2. This part 1-2 only identifies differences from, or supplements to, normal temperature design.
(2)P This Part 1-2 deals only with passive methods of fire protection. Active methods are not covered.
(3)P This Part 1-2 applies to masonry structures which, for reasons of general fire safety, are required to fulfil certain functions when exposed to fire, in terms of:
- avoiding premature collapse of the structure (load bearing function)
- limiting fire spread (flames, hot gases, excessive heat) beyond designated areas (separating function)
(4)P This Part 1-2 gives principles and application rules for designing structures for specified requirements in respect of the aforementioned functions and levels of performance.
(5)P This Part 1-2 applies to structures, or parts of structures, that are within the scope of EN 1996-1-1, EN 1996-2 and EN 1996-3 and are designed accordingly.
(6)P This Part 1-2 does not cover masonry built with Natural Stone units to EN771-6
(7)P This Part 1-2 deals with the following:
- non-loadbearing internal walls.
- non-loadbearing external walls.
- loadbearing internal walls with separating or non-separating functions.
- loadbearing external walls with separating or non-separating functions.
NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.
Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec
PUBLISHED
SRPS EN 1996-1-2:2012
60.60
Standard published
Jul 25, 2012
MINISTARSTVO GRAĐEVINARSTVA, SAOBRAĆAJA I INFRASTRUKTURE