Specifies the general requirements for construction, testing and marking of electrical apparatus and Ex components intended for use in explosive gas atmospheres. Electrical apparatus complying with this standard is intended for use in hazardous areas in which explosive gas atmospheres, caused by mixtures of air and gases, vapours or mists, exist under normal atmospheric conditions. The significant changes with respect to the previous edition are: Requirements for explosive dust atmospheres transferred from IEC 61241-0, The marking Group "II" alone has been replaced by "IIA", "IIB", or "IIC" as many of the enclosure requirements are now aligned with a specific sub-group, Dust groups defined as Group IIIA, IIIB and IIIC, Remainder of "electrostatic" requirements transferred from IEC 60079-26 and Equipment protection levels (EPL) introduced.
The contents of the interpretation sheets of November 2008 and April 2019, and the corrigendum of December 2010 have been included in this copy.
NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.
Equipment and protective systems intended for use in potentially explosive atmospheres (ATEX)
HarmonizedDirective 2008/68/EC of the European Parliament and of the council of 24 September 2008 on the inland transport of the dangerous goods
WITHDRAWN
SRPS EN 60079-0:2008
WITHDRAWN
SRPS EN 60079-0:2011
95.99
Withdrawal of Standard
Nov 29, 2012
WITHDRAWN
SRPS EN 60079-0:2012