SRPS EN 13463-1:2012

Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements

Aug 27, 2012
95.99   Withdrawal of Standard   Mar 24, 2020

General information

95.99     Mar 24, 2020

ISS

N031

European Norm

13.230  

English  

marina

Buying

Withdrawn

Language in which you want to receive the document.

Scope

This European Standard specifies the basic method and requirements for design, construction, testing and marking of non-electrical equipment intended for use in potentially explosive atmospheres in air of gas, vapour, mist and dusts. Such atmospheres can also exist inside the equipment. In addition, the external atmosphere can be drawn inside the equipment by natural breathing produced as a result of fluctuations in the equipment’s internal operating pressure, and/or temperature.
This European Standard is valid for atmospheres having pressures ranging from 0,8 bar to 1,1 bar and temperatures ranging from - 20 °C to + 60 °C., i.e. equipment built to this European Standard will be satisfactory to any service conditions within this range unless otherwise specified.
NOTE 1 The requirements of this European Standard can also be helpful for the design, construction, testing and marking of equipment intended for use in atmospheres outside the validity range stated above. In this case however, the ignition hazard assessment, ignition protection provided, additional testing (if necessary), manufacturer’s technical documentation and instructions to the user, should clearly demonstrate and indicate the equipment’s suitability for the conditions it may encounter. It should also be recognized that changes in temperature and pressure can have a significant influence on ignitability.
This European Standard does not cover additional marking for equipment intended for use outside the scope of its validity such as an oxygen-enriched atmosphere.
This European Standard is also applicable for the design, construction, testing and marking of components, protective systems, devices and assemblies of these products which have possible ignition sources and are intended for use in potentially explosive atmospheres.

Related directives

NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.

94/9/EC

Equipment and protective systems intended for use in potentially explosive atmospheres (ATEX)

Harmonized
2014/34/EU

Directive 2014/34/EU Of The European Parliament And Of The Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres (recast)

Harmonized

Life cycle

NOW

WITHDRAWN
SRPS EN 13463-1:2012
95.99 Withdrawal of Standard
Mar 24, 2020

REVISED BY

PUBLISHED
SRPS EN ISO 80079-36:2017

Related project

Adopted from EN 13463-1:2009