SRPS EN 50176:2012

Stationary electrostatic application equipment for ignitable liquid coating material - Safety requirements

Feb 29, 2012

General information

60.60     Feb 29, 2012

ISS

N031

European Norm

87.100  

English  

van plana za 2011. godinu.

Buying

Published

Language in which you want to receive the document.

Scope

1.1 This European Standard specifies the requirements for stationary electrostatic application equipment for ignitable liquid coating materials and for hard to ignite liquid coating materials to be used in explosive atmospheres generated by their own spray cloud. A distinction is made between spraying systems corresponding to EN 50050 and spraying systems designed for higher discharge energies and/or currents.
This European Standard also specifies the design-related requirements for a safe operation of the stationary equipment including its electrical installation.
1.2 This European Standard considers four types of electrostatic spraying systems; see 5.1 for more details.
1.3 This European Standard deals with all hazards significant for the electrostatic spraying of coating materials, which could also contain small quantities of added metal particles, if the work is carried out under conditions recommended by the manufacturer. In particular, this includes ignition hazards resulting from the generated explosive atmosphere, and the protection of persons from electric shocks.
1.4 This stationary equipment is classified as equipment of group II, category 2G or category 3G for use in potentially explosive areas of zone 1 or 2, respectively.
NOTE For other safety aspects like
– zone classification of the areas in and around spray booths, see EN 12215:2004, 5.7.2.3;
– zone classification of other areas with explosive atmosphere, see EN 60079-10-1;
– selection, installation and application of other electrical and non electrical equipment in areas with explosion hazard, see EN 60079-14 and EN 12215:2004, 5.7.2.5;
– health protection (for instance, noise), see also EN 12215:2004, 5.5 and EN 14462;
– cleaning of spraying areas, see instruction manual of the spraying equipment;
– fire prevention and protection (for instance fire hazards due to other sources) see also EN 12215:2004, 5.7.1.
Design-related measures for reducing the generation of noise of the stationary equipment for electrostatic coating are given in EN ISO 11688 1. See also EN 14462.

Related directives

NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.

94/9/EC

Equipment and protective systems intended for use in potentially explosive atmospheres (ATEX)

Harmonized
2014/34/EU

Directive 2014/34/EU Of The European Parliament And Of The Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres (recast)

Harmonized

Life cycle

PREVIOUSLY

WITHDRAWN
SRPS EN 50176:2010

NOW

PUBLISHED
SRPS EN 50176:2012
60.60 Standard published
Feb 29, 2012

REVISED BY

PROJECT
dnaSRPS EN 50176:2024

Related project

Adopted from EN 50176:2009

National regulations and standards

Сл.гласник РС бр. 72/2017
SPISAK SRPSKIH STANDARDA iz oblasti opreme i zaštitnih sistema namenjenih za upotrebu u potencijalno eksplozivnim atmosferama

МИНИСТАРСТВО ПРИВРЕДЕ