Withdrawn
This Technical Specification specifies a method for quantitative determination of 17 2,3,7,8-chlorine substituted dibenzo-p-dioxins and dibenzofurans and dioxin-like polychlorinated biphenyls in sludge, treated biowaste and soil using liquid column chromatographic clean-up methods and GC/HRMS.
The analytes to be determined with this Technical Specification are listed in Table 2.
(...)
The limit of detection depends on the kind of sample, the congener, the equipment used and the quality of chemicals used for extraction and clean-up. Under the conditions specified in this Technical Specification, limits of detection better than 1 ng/kg (expressed as dry matter) can be achieved.
This method is "performance based". It is permitted to modify the method if all performance criteria given in this method are met.
NOTE In principle this method can also be applied for sediments, mineral wastes and for vegetation. It is the responsibility of the user of this Technical Specification to validate the application for these matrices.
NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.
Protection of the environment, and in particular of the soil, when sewage sludge is used in agriculture
WITHDRAWN
SRPS CEN/TS 16190:2013
95.99
Withdrawal of Standard
Feb 28, 2020
PUBLISHED
SRPS EN 16190:2019