delSRPS EN 50131-3:2010/corrigendum:2024

Alarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment

General information

50.98     Apr 16, 2024

ISS

N079

European Norm

13.310  

French  

Напушта се из разлога што је коригендум само на француском.

Scope

This standard specifies the requirements, performance criteria and testing procedures for control and indicating equipment (CIE) intended for use in intrusion and hold-up alarm systems (I&HAS) installed in buildings. This document also applies to CIE to be used in IAS or HAS. The CIE may incorporate processing functions of other I&HAS components or its processing requirements may be distributed among such components. This standard specifies the requirements for CIE installed in buildings using specific or non-specific wired interconnections or wire-free interconnections. These requirements also apply to ACE that are installed inside or outside of the supervised premises and mounted in indoor or outdoor environments. Where CIE shares means of detection, interconnection, control, communication, processing and/or power supplies with other applications, these requirements apply to I&HAS functions only. This standard specifies performance requirements for CIE at each of the four security grades identified in the European Standard EN 50131-1, “Alarm Systems – Intrusion and hold-up systems – System requirements”. Requirements are also specified for four environmental classes covering applications for indoor and outdoor locations. This standard includes mandatory functions, which shall be provided on all CIE for the appropriate security grade, as well as optional functions that may additionally be provided. This standard does not deal with requirements for compliance with EU regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except in that it specifies the equipment operating conditions for EMC susceptibility testing as required by EN 50130-4. NOTE In this standard reference to the term “I&HAS” is used throughout, except where there is specific need to differentiate between the IAS and HAS portions of a system. The term is intended to include IAS and HAS when such systems are installed separately.

Life cycle

NOW

ABANDON
delSRPS EN 50131-3:2010/corrigendum:2024
50.98 Project deleted
Apr 16, 2024

Related project

Adopted from EN 50131-3:2009/corrigendum Dec. 2010 IDENTICAL