Residential solid fuel burning appliances - Part 2-6: Mechanically by wood pellets fed roomheaters, inset appliances and cookers

General information

50.98     Oct 11, 2018

ISS

M295

European Norm

97.100.30  

English  

Scope

This part 2-6 of a European Standard series is applicable to space heaters, inset appliances and cookers fired by wood pellets, mechanically fed up to 50 kW nominal heat output. These appliances typically use auxiliary energy which is measured in this standard as well.
For inset appliances and especially their testing, additional information may be necessarry from prEN 16510 2 2.
Non mechanically fed appliances burning solid mineral fuels, peat briquettes and natural or manufactured wood logs are not included in this European Standard, but are covered by prEN 16510 2 1 to prEN 16510 2 5.
NOTE These appliances may have an integral fuel hopper or be combined with an external fuel hopper.
This European Standard should be used in conjunction with EN 16510 1.
The appliances covered by this part 2-6 provide heat into the space where they are installed. They may be operated with either natural draught or fan-assisted combustion air. Where fitted with a boiler, they can also provide domestic hot water and/or central heating. These appliances burn wood pellets only, in accordance with the appliance manufacturer's instructions. They only operate with the firedoors closed.
NOTE A fan-assisted appliance does still operate under negative pressure in the flue gas system.
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emissions), instructions and marking together with associated test methods and test fuels.
This European Standard is not applicable to appliances:
- with boiler intended for water systems having water temperatures above 110°C and 3 bar; and
- with boiler intendend for water systems having direct contact with sanitary hot water;
- intended to be used with a pure horizontal exhaust (through the building wall);
- with flue gas condensation in the appliance;
- switching on / off for part load operation

Related directives

NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.

89/106/EEC

Construction products

305/2011

Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec

Life cycle

NOW

ABANDON
delSRPS EN 16510-2-6:2017
50.98 Project deleted
Oct 11, 2018

Related project

Adopted from FprEN 16510-2-6