SRPS EN IEC 62541-14:2020

OPC unified architecture - Part 14: PubSub

Dec 31, 2020

General information

90.93     Jan 5, 2026

90.00    Jan 5, 2031

ISS

N065

European Norm

25.040.40     35.100.05  

English  

Buying

Published

Language in which you want to receive the document.

Scope

IEC 62541-14:2020 defines the OPC Unified Architecture (OPC UA) PubSub communication model. It defines an OPC UA publish subscribe pattern which complements the client server pattern defined by the Services in IEC 62541-4. IEC TR 62541-1 gives an overview of the two models and their distinct uses.

PubSub allows the distribution of data and events from an OPC UA information source to interested observers inside a device network as well as in IT and analytics cloud systems.

This document consists of

• a general introduction of the PubSub concepts,

• a definition of the PubSub configuration parameters,

• mapping of PubSub concepts and configuration parameters to messages and transport protocols, and

• a PubSub configuration model.

Not all OPC UA Applications will need to implement all defined message and transport protocol mappings. IEC 62541-7 defines the Profile that dictates which mappings need to be implemented in order to be compliant with a particular Profile.

Life cycle

NOW

PUBLISHED
SRPS EN IEC 62541-14:2020
90.93 Standard confirmed
Jan 5, 2026

REVISED BY

PUBLISHED
SRPS EN IEC 62541-14:2026

Related project

Adopted from EN IEC 62541-14:2020

Adopted from IEC 62541-14:2020 ED1 IDENTICAL