This document covers the design and manufacturing, installation and testing, operation and maintenance of vehicle fuelling appliances (VFA) for domestic fuelling of vehicles with compressed natural gas (CNG).
This document is applicable to VFAs having the following technical limits:
- maximum compressing capacity: 20 Nm3/h (NTP);
- maximum internal storage volume for outdoor installation: 400 l;
- maximum gas outlet pressure: 200 bar at 15 °C;
This document is applicable to VFAs supplied with natural gas as defined in local applicable gas composition regulations or EN 16723 2, or with other gases meeting these requirements including biomethane, upgraded coal-bed methane (CBM) and gas from liquefied natural gas (LNG) vaporizer (on-site or off-site).
This document applies to VFAs not incorporating gas outlet metering systems.
NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.
Directive 2014/68/EU of the European Parliament and of the Council of 15 May 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of pressure equipment
Directive 2014/94/EU of The European Parliament and of The Council of 22 October 2014 on the deployment of alternative fuels infrastructure
ABANDON
delSRPS EN 17278:2017
40.98