SRPS EN IEC 60584-3:2021

Thermocouples - Part 3: Extension and compensating cables - Tolerances and identification system

Jun 30, 2021

General information

60.60     Jun 30, 2021

ISS

N065

European Norm

17.200.20  

English  

Buying

Published

Language in which you want to receive the document.

Scope

IEC 60584-3:2021 It is necessary for thermocouple temperature measurement that the electro-motive force (abbreviated as e.m.f. hereafter) of the thermocouple circuit is precisely measured by a measuring instrument. A thermocouple is electrically connected to the instrument by a proper pair of electric cables. IEC 60584-3:2021 standardizes these cables. It specifies identification and manufacturing tolerances for extension and compensating cables (mineral insulated extension and compensating cables are not included) provided directly to users of industrial processes. These tolerances are determined with respect to the e.m.f. ver-sus temperature relationship of IEC 60584-1. The requirements for extension and compensating cables for use in industrial process control are specified.

Life cycle

PREVIOUSLY

WITHDRAWN
SRPS EN 60584-3:2009

NOW

PUBLISHED
SRPS EN IEC 60584-3:2021
60.60 Standard published
Jun 30, 2021

Related project

Adopted from EN IEC 60584-3:2021

Adopted from IEC 60584-3:2021 ED3 IDENTICAL