60.60 Mar 31, 2026
ISS
European Norm
English
The standard is being translated and is in the "40.60 Close of voting" state. view more ...
Published
This document specifies three procedures, A, B and C, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions, biodiesel and other liquids in the temperature range of 40 °C to 370 °C.
NOTE 1 Although, technically, kerosene with a flash point above 40 °C can be tested using this document, it is standard practice to test kerosene according to ISO 13736.[5] Similarly, lubricating oils are normally tested according to ISO 2592.[2]
Procedure A is applicable to distillate fuels (diesel, biodiesel blends, heating oil and turbine fuels), new and in-use lubricating oils, paints and varnishes, and other homogeneous liquids not included in the scope of procedures B or C.
Procedure B is applicable to residual fuel oils, cutback residuals, used lubricating oils, mixtures of liquids with solids, and liquids that tend to form a surface film under test conditions or are of such kinematic viscosity that they are not uniformly heated under the stirring and heating conditions of procedure A.
Procedure C is applicable to fatty acid methyl esters (FAME) as specified in specifications such as EN 14214[11] or ASTM D6751.[13]
This document is not applicable to water-borne paints and varnishes.
NOTE 2 Water-borne paints and varnishes can be tested using ISO 3679.[3] Liquids containing traces of highly volatile materials can be tested using ISO 1523[1] or ISO 3679.
WITHDRAWN
SRPS EN ISO 2719:2017
WITHDRAWN
SRPS EN ISO 2719:2017
WITHDRAWN
SRPS EN ISO 2719:2017/A1:2021
PUBLISHED
SRPS EN ISO 2719:2026
60.60
Standard published