SRPS EN ISO 10993-18:2020

Biological evaluation of medical devices - Part 18: Chemical characterization of medical device materials within a risk management process (ISO 10993-18:2020)

Nov 30, 2020
Nov 30, 2022

General information

60.60     Nov 30, 2020

ISS

Z076

European Norm

11.100.20  

English   Serbian  

Наслов документа на српском језику је унапређен и гласи „Биолошко вредновање медицинских средстава — Део 18: Хемијска карактеризација материјала медицинских средстава у оквиру процеса менаџмента ризиком"
Terms

Buying

Published

Language in which you want to receive the document.

Scope

This document specifies a framework for the identification, and if necessary, quantification of constituents of a medical device, allowing the identification of biological hazards and the estimation and control of biological risks from material constituents, using a generally stepwise approach to the chemical characterization which can include one or more of the following:
— the identification of its materials of construction (medical device configuration);
— the characterization of the materials of construction via the identification and quantification of their chemical constituents (material composition);
— the characterization of the medical device for chemical substances that were introduced during manufacturing (e.g. mould release agents, process contaminants, sterilization residues);
— the estimation (using laboratory extraction conditions) of the potential of the medical device, or its materials of construction, to release chemical substances under clinical use conditions (extractables);
— the measurement of chemical substances released from a medical device under its clinical conditions of use (leachables).
This document can also be used for chemical characterization (e.g. the identification and/or quantification) of degradation products. Information on other aspects of degradation assessment are covered in ISO 10993-9, ISO 10993-13, ISO 10993-14 and ISO 10993-15.
The ISO 10993 series is applicable when the material or medical device has direct or indirect body contact (see ISO 10993-1 for categorization by nature of body contact).
This document is intended for suppliers of materials and manufacturers of medical devices, to support a biological evaluation.

Related directives

NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.

90/385/EEC

Active implantable medical devices

Harmonized
93/42/EEC

Medical devices

Harmonized
2007/47/EC

Directive 2007/47/EC of the European Parliament and of the council of 5 September 2007 amending Council Directive 90/385/EEC on the approximation of the laws of the Member States relating to active implantable medical devices, Council Directive 93/42/EEC concerning medical devices and Directive 98/8/EC concerning the placing of biocidal products on the market

2017/745

Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on medical devices, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directives 90/385/EEC and 93/42/EEC

Harmonized

Life cycle

PREVIOUSLY

WITHDRAWN
SRPS EN ISO 10993-18:2011

NOW

PUBLISHED
SRPS EN ISO 10993-18:2020
60.60 Standard published
Nov 30, 2020

Related project

Adopted from EN ISO 10993-18:2020

Adopted from ISO 10993-18:2020