mid-tone spread
Description

S

difference between maximum and minimum deviations of tone values (print) for chromatic plates and defined by the equation

where

          Ac     is the measured tone value of the cyan process colour image;

        Ac0    is the specified tone value of the cyan process colour image;

        Am     is the measured tone value of the magenta process colour image;

        Am0   is the specified tone value of the magenta process colour image;

        Ay     is the measured tone value of the yellow process colour image;

EXAMPLE 1      For measured values Ac = 22, Am17 and Ay = 20 and specified values Ac0 = 20, Am0 = 20 and Ay0 = 18):

EXAMPLE 2      S = max[(22−20),(17−20),(20−18)] − min[(22−20),(17−20),(20−18)] = 2−(−3) = 5.

        Ay0    is the specified tone value of the yellow process colour image.

Serbian

Name
No information
Description
No information

Serbian

Name
расејање у средњим тоновима
Description

S

разлика између максималне и минималне девијације тонске вредности (отиска) за хроматске сепарације дефинисана једначином

где је:

Ac       измерена тонска вредност цијана;

        Ac0           утврђена тонска вредност цијана;

        Am      измерена тонска вредност магенте;

        Am0     утврђена тонска вредност магенте;

Ay       измерена тонска вредност жуте;

        Ay0     утврђена тонска вредност жуте;

ПРИМЕР 1 За измерене вредности Ac = 22, Am=17 и Ay = 20 и утврђене вредности Ac0 = 20, Am0 = 20 и Ay0 = 18):

ПРИМЕР 2 S \= max[(22−20),(17−20),(20−18)] − min[(22−20),(17−20),(20−18)] = 2−(−3) = 5.