SRPS EN ISO 25539-3:2024

Cardiovascular implants - Endovascular devices - Part 3: Vena cava filters (ISO 25539-3:2024)

Nov 29, 2024

General information

60.60     Nov 29, 2024

ISS

Z076

European Norm

11.040.40  

English  

Buying

Published

Language in which you want to receive the document.

Scope

This document specifies the requirements for the evaluation of vena cava filter systems (filters and delivery systems) and the requirements with respect to nomenclature, design attributes and information supplied by the manufacturer. Guidance for the development of in vitro test methods is included in Annex D. This document is intended to be used in conjunction with ISO 14630, which specifies general requirements for the performance of non-active surgical implants.
NOTE 1       Due to the variations in the design of implants covered by this document, and in some cases due to the emergence of novel types of such implants, acceptable standardized in vitro tests and clinical results are not always available. As further scientific and clinical data become available, a revision of this document will be necessary.
This document is applicable to vena cava filters intended to prevent symptomatic pulmonary embolism by capturing blood clots in the inferior vena cava (IVC). While this document can be useful with respect to filters implanted in other venous locations (e.g. superior vena cava, iliac veins), it does not specifically address the use of filters in other implantation sites.
This document is also applicable to permanent filters together with their associated delivery systems, optional filters that can be retrieved and their associated retrieval systems, and convertible filters and their associated conversion systems. While this document can be useful with respect to the evaluation of repositioning filters after chronic implantation, it does not specifically address filter repositioning.
This document is not applicable to
—           temporary filters (e.g. tethered) that need to be removed after a defined period of time,
—           issues associated with viable tissues and non-viable biological materials, and
—           procedures and devices (e.g. venous entry needle) used prior to the vena cava filter procedure.
Although absorbable filters and filters with absorbable coatings are within the scope of this document, this document is not comprehensive with respect to the absorbable properties of these devices.
NOTE 2       Absorbable implants are covered in ISO/TS 17137.
Although coated filters and coated filter systems are within the scope of this document, this document is not comprehensive with respect to coatings.
NOTE 3       Vascular device-drug combination products are covered in ISO 12417-1 and some coating properties are covered in ISO 25539-4.

Related directives

NOTE: If the word "harmonized" (marked in green) is not found in the field with the name of the directive, it means that the European standard is not cited in the OJEU.

2017/745

Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on medical devices, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directives 90/385/EEC and 93/42/EEC

Life cycle

PREVIOUSLY

WITHDRAWN
SRPS EN ISO 25539-3:2013

NOW

PUBLISHED
SRPS EN ISO 25539-3:2024
60.60 Standard published
Nov 29, 2024

Related project

Adopted from EN ISO 25539-3:2024 IDENTICAL

Adopted from ISO 25539-3:2024 IDENTICAL