IEC 61674:2012 ED2

Medical electrical equipment - Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging
29. 11. 2012.

Опште информације

99.60     9. 7. 2024.

IEC

TC 62/SC 62C

Međunarodni standard

11.040.50  

engleski   francuski  

Kupovina

Revidiran

Jezik na kome želite da primite dokument.

Apstrakt

IEC 61674:2012 specifies the performance and some related constructional requirements of diagnostic dosimeters intended for the measurement of air kerma, air kerma length product or air kerma rate, in photon radiation fields used in radiography, including mammography, radioscopy and computed tomography, for X-radiation with generating potentials not greater than 150 kV. This International Standard is applicable to the performance of dosimeters with vented ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging. The object of this standard is to establish requirements for a satisfactory level of performance for diagnostic dosimeters, and to standardize the methods for the determination of compliance with this level of performance. This standard is not concerned with the safety aspects of dosimeters. The diagnostic dosimeters covered by this standard are not intended for use in the patient environment and, therefore, the requirements for electrical safety applying to them are contained in IEC 61010-1. This second edition cancels and replaces the first edition and constitutes a technical revision.

Životni ciklus

PRETHODNO

POVUČEN
IEC 61674:1997 ED1

POVUČEN
IEC 61674:1997/AMD1:2002 ED1

TRENUTNO

POVUČEN
IEC 61674:2012 ED2
99.60 Povlačenje stupilo na snagu
9. 7. 2024.

REVIDIRAN OD

OBJAVLJEN
IEC 61674:2024 ED3