Telefon: (011) 7541-421, 3409-301, 3409-335, 6547-293, 3409-310
E-mail: Prodaja standarda: prodaja@iss.rs Seminari, obuke: iss-edukacija@iss.rs Informacije o standardima: infocentar@iss.rs
Stevana Brakusa 2, 11030 Beograd
Glavni meni

IEC 60317-48:2012 ED2

Specifications for particular types of winding wires - Part 48: Glass-fibre wound resin or varnish impregnated, bare or enamelled round copper wire, temperature index 155
9. 7. 2012.

Опште информације

60.60     9. 7. 2012.

IEC

TC 55

Međunarodni standard

29.060.10  

engleski   francuski   španski  

Kupovina

Objavljen

Jezik na kome želite da primite dokument.

Apstrakt

IEC 60317-48:2012 specifies requirements of glass-fibre wound resin or varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 155. The impregnating agent can be, for instance, polyester or polyesterimide resin based. For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. This edition includes the following significant technical changes with respect to the previous edition:
- new subclause containing general notes on winding wire,
- formerly part of the scope,
- new subclause containing requirements for appearance,
- new Clause 23, Pin hole test. Keywords: copper winding wire

This publication is to be read in conjunction with IEC 60317-0-6:2001.

Životni ciklus

PRETHODNO

POVUČEN
IEC 60317-48:1999 ED1

TRENUTNO

OBJAVLJEN
IEC 60317-48:2012 ED2
60.60 Standard objavljen
9. 7. 2012.