Telefon: (011) 7541-421, 3409-301, 3409-335, 6547-293, 3409-310
E-mail: Prodaja standarda: prodaja@iss.rs Seminari, obuke: iss-edukacija@iss.rs Informacije o standardima: infocentar@iss.rs
Stevana Brakusa 2, 11030 Beograd
Glavni meni

IEC 61094-3:2016 ED2

Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique
14. 6. 2016.

Опште информације

60.60     14. 6. 2016.

IEC

TC 29

Međunarodni standard

17.140.50     33.160.50  

engleski   francuski   španski  

Kupovina

Objavljen

Jezik na kome želite da primite dokument.

Apstrakt

IEC 61094-3:2016 specifies a primary method of determining the complex free-field sensitivity of laboratory standard microphones so as to establish a reproducible and accurate basis for the measurement of sound pressure under free-field conditions. It is applicable to laboratory standard microphones meeting the requirements of IEC 61094-1. It is intended for use by laboratories with highly experienced staff and specialized equipment. This second edition cancels and replaces the first edition published in 1995. This edition constitutes a technical revision.
The contents of the corrigendum of December 2016 have been included in this copy.

Životni ciklus

PRETHODNO

POVUČEN
IEC 61094-3:1995 ED1

TRENUTNO

OBJAVLJEN
IEC 61094-3:2016 ED2
60.60 Standard objavljen
14. 6. 2016.

ISPRAVKE / IZMENE

OBJAVLJEN
IEC 61094-3:2016/COR1:2016 ED2