delSRPS EN ISO 11608-5:2018

Injekcioni sistemi sa iglom za medicinsku upotrebu — Zahtevi i metode ispitivanja — Deo 5: Automatizovane funkcije

Needle-based injection systems for medical use - Requirements and test methods - Part 5: Automated functions (ISO/FDIS 11608-5:2021)

Опште информације

50.98     21. 9. 2022.

90.00    15. 2. 2027.

ISS

Z076

Evropski standard

11.040.25  

engleski  

Apstrakt

This document specifies requirements and test methods for automated functions in needle-based injection systems with automated functions (NIS-AUTO).
General requirements are provided for all automated functions. In addition, specific requirements are provided for the following automated functions:
a) medicinal product preparation (e.g. reconstitution);
b) needle preparation;
c) needle hiding;
d) priming;
e) dose setting;
f) needle insertion;
g) injection depth control;
h) injection of the medicinal product;
i) recording of device functions;
NOTE  This document does not cover remote communication from the NIS-AUTO (pertains to wired and wireless communication transfer from the NIS auto).
j) disabling the NIS-AUTO;
k) needle retraction;
l) needle shielding;
m) needle removal.