Pretražite srpske, evropske i međunarodne standarde. Odredite organizaciju koja je donosilac standarda, izaberite oznaku standarda ili ključnu reč i završite željenu pretragu. Možete dodati i fazu u izradi standarda ili komitet/komisiju koja je izradila standard.
Direct acting indicating analogue electrical measuring instruments and their accessories title - Part 4: Special requirements for frequency meters
60.60 Standard objavljen
Direct acting indicating analogue electrical measuring instruments and their accessories - Part 5: Special requirements for phase meters, power factor meters and synchroscopes
60.60 Standard objavljen
Direct acting indicating analogue electrical measuring instruments and their accessories - Part 6: Special requirements for ohmmeters (impedance meters) and conductance meters
60.60 Standard objavljen
Direct acting indicating analogue electrical measuring instruments and their accessories - Part 7: Special requirements for multi-function instruments
60.60 Standard objavljen
Direct acting indicating analogue electrical measuring instruments and their accessories - Part 8: Special requirements for accessories
60.60 Standard objavljen
Direct acting indicating analogue electrical measuring instruments and their accessories - Part 9: Recommended test methods
60.60 Standard objavljen
Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) - Part 1: Tests on cables and their accessories
60.60 Standard objavljen
Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) - Part 1: Tests on cables and their accessories
60.60 Standard objavljen
Amendment 1 - Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) - Part 1: Tests on cables and their accessories
60.60 Standard objavljen
Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables). Part 2: General and construction requirements
60.60 Standard objavljen
Amendment 1 - Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables). Part 2: General and construction requirements
60.60 Standard objavljen
Amendment 2 - Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) - Part 2: General and construction requirements
60.60 Standard objavljen
High-voltage test techniques - Part 1: General terminology and test requirements
60.60 Standard objavljen
High-voltage test techniques - Part 2: Measuring systems
60.60 Standard objavljen